AIRMAX Cat6 UTP Cable – 305mtr 23AWG Blue Category 6 solution is guaranteed to exceed specifications as set down in International standards.Our AIRMAX CAT6 solution comprises Category 6 component compliant patch panels, keystones and patch cords. When combined with AirPro’s Category 6 UTP cable, an end-to-end channel exists that maximises data throughput and provides headroom for all future technologies operating beyond one Gigabit.
AIR-MAX CAT6 UTP 23AWG PVC Cable
AIR-MAX CAT6 UTP 23AWG PVC Cable
- Conductor sizes for Cat.6 are set at 23AWG.
- By keeping the gauge size of the conductor larger, there is less heat generation caused and less drop of voltage over distance.
- Exceeds current ANSI/TIA and ISO Standards for performance.
- Capable of handling the latest ver. of power over Ethernet.
- Cable has been tested over 500Mhz and has shown performance testing results allowing 10Gbit Ethernet transmission up to a length of 70mtrs.
General Details
Application
- Voice; ISDN
- 100BASE-T Ethernet (IEEE802.3)
- 155/622Mbps 1.2/2.4 Gbps ATM
- 1000Mbps Gigabit Ethernet
- 550MHz Broadband Video
Performance Statistics
Frequency Mhz |
Insertion Loss dB/100mtrs |
NEXT (dB) |
Return Loss (dB) |
1 | 1.8 | 78.0 | 37.8 |
4 | 3.0 | 76.0 | 36.5 |
10 | 5.2 | 70.0 | 31.0 |
16 | 6.8 | 68.0 | 31.0 |
20 | 7.6 | 64.0 | 31.0 |
31.25 | 9.3 | 62.5 | 30.0 |
62.5 | 13.2 | 60.0 | 30.0 |
100 | 18.1 | 57.0 | 29.0 |
200 | 26.1 | 52.5 | 27.0 |
250 | 28.9 | 50.0 | 25.1 |
300 | 31.8 | 46.0 | 23.4 |
400 | 36.5 | 43.0 | 21.9 |
500 | 41.8 | 42.0 | 20.6 |
Specifications
Construction | |
Conductor | |
Material | Bare Copper |
Wire Size | 23AWG |
Diameter | 0.56mm |
Insulation | |
Material | PE |
Diameter | Nominal: 1.011 mm |
Colors | Blue/White-Blue | Orange/White-Orange | Green/White-Green | Brown/White-Brown |
Unaged Elongation(%) | Min. 300% |
Unaged Tensile Strength | Min. 1.683 Kgf/mm² |
Jacket | |
Material | Flame Retardant PVC |
Thickness | 0.5±0.02 mm |
Diameter | 6.0±0.2 mm |
Color | Gray standard (Assorted upon request) |
Fire Rated Class | CM |
Physical Ranges | |
Insulation | |
Min. Tension Strength | |
Before Aging | Min. 1.683 Kgf/mm² |
After Aging | 75% before aging (100℃ X 48hrs) |
Min Elongation(%) | |
Before Aging | 300% |
After Aging | 75% before aging (100℃ X 48hrs) |
Jacket | |
Min. Tension Strength | |
Before Aging | Min. 1.407 Kgf/mm² |
After Aging | 75% before aging (100℃ X 168hrs) |
Min Elongation(%) | |
Before Aging | Min. 100% |
After Aging | 50% before aging (100℃ X 168hrs) |
Cold Bend Test | -20 ± 2℃ x 4hrs no. crack |
Dielectric Strength | 2500 V dc / 2 seconds |
Min. Bending Radius | 50mm |
Max. Pulling Tension | 25 lbs |
Installation Temperature | 0℃ to +50℃ |
Operating Temperature | -20℃ to +70℃ |
Electrical | |
Conductor Resistance | Max. 7.32 Ω/100m at 20℃ |
DC Resistence Unbalance | Max. 2% |
Pair-to-Ground Capacitance Unbalance | Max. 160 pF/100m |
Dielectric Strength of Insulation | 2500 V dc / 2 seconds |
Insulation Resistence Test | Min. 5000 MΩ·Km |
Mutual Capacitance | Max. 5600 pF/100m |
Impedance 1~100MHz | 100Ω ± 15% |
Impedance 100-250MHz | 100Ω ± 22% |